6. Existing Programmer / Time Clock - any existing programmer or time clock is now redundant. You should either program it to be permanently on (24/7) or preferably remove it, ensuring that the two wires it was switching are safely electrically linked together, preferably by installing a link wire within the heating system. Please check heating system manufacturers wiring instructions for further details.
7. Finally check that the Room Sensor is functioning correctly and switching the heating system on and off correctly. A simple test for this is to press and hold the Comfort (+) button for 5 seconds. This will activate the Boost mode and turn the heating system on. Check that the web dashboard Heating widget is now showing that the Boost is activated and the heating system is running (Red-glow around house icon at top of Heating widget).
8. Handover - Please ensure you handover this document to the householder and direct them to the Heating & Hot Water Control User Manual available for download by click- ing on Manuals on the web dashboard (lower right).
© 2 Save Energy Limited 2014 17