Page 16 - OWL Intuition Manuals
P. 16
c.
Wiring - All necessary electrical connections should now be made.
• The Room Sensor is double insulated and does not require an earth connection.
• An earth connection block is provided on the backplate for terminating any cable
earth conductors.
• Earth continuity must be maintained and all bare earth conductors must be sleeved.
• If one of the existing wires is a Neutral supply then this should be ‘parked’ on the
terminal labelled ‘N’.
• Ensure that no conductors are left protruding outside the central space enclosed by
the backplate.
• Please ensure that all installations comply with the current IEE regulations.
• Please consult the heating system manufacturers installation instructions before
making these connections and note that a link may need to be removed when con-
necting external controls.
Fit Safety Cover - Check all of the wiring is safely attached to the appropriate back-
plate terminals and the screws are tight. Then fit the Safety Cover by clipping it into place over the wiring terminals.
Complete the installation by mounting the Room Sensor to the backplate. To do this engage the Room Sensor on the lugs at the top of the backplate, then carefully swing the Room Sensor down and push it carefully back into its plug-in terminal connectors.
Locate over the captive screws at the base of the backplate and tighten them so that the Room Sensor is locked into position.
4. 5.
16
© 2 Save Energy Limited 2014