a. Ensure that the Live feed to the Room Sensor is correctly fused (3A or 5A maximum) - This protection is normally provided by way of a fused spur powering the heating system.
b. Fix the backplate - Offer the backplate supplied to the wall in the position where the Room Sensor is to be mounted (with the cable through the central aperture of the backplate) and mark the fixing positions through the slots in the backplate. Drill and plug the wall, then secure the plate into position. The slots in the backplate will compensate for minor misalignment of the fixings.
OWL Intuition-c Heating Control Room Sensor Backplate Wiring
Terminal
Description
N
Neutral - Not used, may be used to ‘park’ unused neutral wire.
L
Live - Not used, may be used to ‘park’ unused live wire.
1
Common terminal of Room Sensor latching relay
2
Not used
3
‘Heat Satisfied’ - Normally closed terminal of Room Sensor latching relay
4
‘Call for Heat’ - Normally open terminal of Room Sensor latching relay
Earth continuity connection