Page 10 - OWL Intuition Manuals
P. 10
STEP FOUR - Install Transmitter and attach Sensors IMPORTANT:
• You must ensure that each Sensor is ONLY around the live core and NOT around a
sheathed cable containing live, neutral and earth.
• The Sensors must be a loose fit onto the cables.
• After the Sensors have been installed, the Transmitter should be hung on the wall in a
free area as far from large metal objects as possible.
In the section BEFORE YOU START on page 3 you will have determined whether you are installing an Intuition-pv Type 1 (solar PV - Henley block) OR an Intuition-pv Type 2 (solar PV - Consumer unit) system. Please now follow the relevant sub-section below, referring to the diagrams on pages 4 and 5 as required.
Intuition-pv Type 1 (solar PV - Henley block)
Consumption Sensor - Locate the supply cables between the Henley block and con- sumer unit (fuse box). Using the latch, clamp the first Sensor around the insulated Live cable going into the consumer unit. Plug this Sensor into the Transmitter left hand socket. The orientation of this Sensor is not important.
Generation Sensor - Locate the PV generated power cable between the Henley block and Generation meter / Inverter. Using the latch, clamp the second Sensor around the insulated Live cable going into the Henley Block. Plug this Sensor into the Transmitter centre socket. The orientation of this Sensor is not important.
• •
10
© 2 Save Energy Limited 2014