Installation Instructions
STEP ONE - Installing the Relay Unit
The Relay Unit should be located on an internal wall approximately 1500mm above floor level, you must use the backplate provided. It should be positioned away from draughts, direct heat and sunlight. The backplate is suitable for direct wall mounting using two wood screws No. 6 x 1” or M3.5 x 25mm into correctly sized wall plugs if required. Alterna- tively mount on to a single gang flush wiring box complying with BS4662, using two M3.5 screws.
1. 2.
Ensure there will be enough space to allow easy screwdriver access to the two cap- tive screws located at the base of the backplate.
Electrical Connections: - If in any doubt whatsoever, do not continue, but consult a qualified electrician or heating engineer.
WARNING: ISOLATE THE MAINS SUPPLY BEFORE COMMENCING INSTALLATION
For existing wireless installations, remove the old relay box to expose the wiring back to the heating system / wiring centre. Check the wiring at both ends to correctly identify which wire is Live, Neutral, Switched Live and any Earth connec- tions.
For new installations, run a new cable between the heating system and chosen Relay Unit Location. The recommended cable size is 1.0mm2. See diagram below.
4